pH Benchtop Meters at a glance
| Product
|
Measures
|
Memory
|
pH
Calibration
|
RS-232
|
| pH 700 Benchtop Meter
|
pH, mV, and temperature (°C or F)
|
Up to 100 data sets
|
Up to 5 points (USA: 1.68,4.01, 7.00, 10.01, 12.45 or NIST: 1.68,4.01, 6.86, 9.18, 12.45) with autobuffer recognition
|
-
|
| ION 700 Benchtop Meter
|
pH, mV, Ion, and Temperature (°C or F)
|
Up to 100 data sets
|
Up to 5 points (USA: 1.68,4.01, 7.00, 10.01, 12.45 or NIST: 1.68,4.01, 6.86, 9.18, 12.45) with autobuffer recognition
|
-
|
| pH 500 Economy Benchtop Meter
|
pH, mV, °C
|
-
|
Up to three points (4.01, 7.00, 10.00)
|
-
|
| pH 2700 Benchtop Meter
|
pH, ORP (mV/Rel. mV), and temperature(°C or F)
|
Up to 500 data sets with time-date stamping for GLP compliance
|
Up to 6 preset or 5 custom with autobuffer recognition of USA, DIN, NIST, User-defined, and Custom buffer sets
|
Bi-directional RS-232; includes software
|
| ION 2700 Benchtop Meter
|
pH, ORP (mV/Rel. mV), and temperature(°C or F)
|
Up to 500 data sets with time-date stamping for GLP compliance
|
Up to 6 preset or 5 custom with autobuffer recognition of USA, DIN, NIST, User-defined, and Custom buffer sets
|
Bi-directional RS-232; includes software
|
| PC 2700 Benchtop Meter
|
pH, ORP (mV/Rel. mV), conductivity, TDS, salinity, resistivity and temperature(°C or F)
|
Up to 500 data sets with time-date stamping for GLP compliance
|
Up to 6 preset or 5 custom with autobuffer recognition of USA, DIN, NIST, User-defined, and Custom buffer sets
|
Bi-directional RS-232; includes software
|
| pH/CON 700 Benchtop Meter
|
pH, mV, conductivity, total dissolved solids (TDS), and temperature (°C or F)
|
Up to 100 data sets
|
Up to 5 points (USA: 1.68,4.01, 7.00, 10.01, 12.45 or NIST: 1.68,4.01, 6.86, 9.18, 12.45) with autobuffer recognition
|
-
|
| pH 510 Benchtop Meter
|
pH, mV, °C
|
up to 50 sets
|
Up to 3 points; select USA (4.01, 7.00, 10.01) or NIST (4.01, 6.86, 9.18) buffer sets
|
-
|
| ION 510 Benchtop Meter
|
Ion, mV, pH, °C
|
up to 50 sets
|
Up to 3 points; select USA (4.01, 7.00, 10.01) or NIST (4.01, 6.86, 9.18) buffer sets
|
-
|
| pH 1000 Benchtop Meter
|
pH, mV, Relative mV, °C
|
up to 16 sets with date and time
|
Up to five customizable calibration points or 1.68, 4.01, 7.00, 10.00, 12.45 with auto buffer recognition
|
Yes
|
| pH 1100 Benchtop Meter
|
pH, mV, Relative mV, °C, °F
|
up to 100 readings with date and time
|
Up to 5 customizable calibration points, or USA, NIST, BF1, or BF2 standard buffer sets
|
Yes
|
| pH 2100 Benchtop Meter
|
pH, mV, Relative mV, Ion, °C, °F
|
up to 100 readings with date and time
|
Up to 5 customizable calibration points, or USA, NIST, Bf1, or BF2 standard buffer sets
|
Yes
|
| pH/CON 510 Benchtop Meter
|
pH, mV, Conductivity, TDS, °C, °F
|
-
|
up to 5 points: select USA (1.68, 4.01, 7.00, 10.00, 12.45) and NIST (1.68, 4.01, 6.86, 9.18, 12.45)
|
-
|
|
|